Product Details:
Payment & Shipping Terms:
|
Model Number: | ELG-150-12 | Output Power: | 150W |
---|---|---|---|
Output Type: | Single | Working Voltage: | 100 ~ 305VAC 142 ~ 431VDC |
Output Voltage: | 12VDC | Output Current: | 12.5A |
The Shell Material: | Metal | Warranty: | 3 Years |
Certification: | CE CB EMC UL TUV PSE | Efficiency: | 88% |
Working Tempera: | -40+90℃ | MOQ: | 1pcs |
High Light: | constant current power supply,meanwell led driver |
5 Years Warranty ELG-150 Dimmable AC - DC 150W 12V Waterproof Led Driver
ELG Series led driver Features:
1. Bulit-in active PFC function
2. Protections: short circuit / over current / over voltage / over temperature
3. No load power consumption<0.5w
4. IP67 / IP65 for indoor outdoor installations
5. Three in one dimming functionresistance
6. 5 years warranty
7. Metal housing design
8. Typical lifetime > 50000 hours
Led Driver Parameter
Model |
ELG-150-12 |
ELG-150-24 |
ELG-150-36 | ELG-150-42 | ELG-75-48 | ELG-75-54 | |
OUTPUT |
DC VOLTAGE |
12V |
24V |
36V | 42V | 48V | 54V |
CONSTANT CURRENT REGION |
6~12V |
12~24V |
18~36V |
21~42V |
24~48V |
27~54V |
|
RATED CURRENT |
10A |
6.25A |
4.17A |
3.57A |
3.13A |
2.8A |
|
Rated POWER |
120W |
150W |
150.1W |
150W |
150.2W |
151.2W |
|
RIPPLE & NOISE (max.) |
150mVp-p |
200mVp-p |
250mVp-p |
250mVp-p |
250mVp-p |
350mVp-p |
|
CURRENT ADJ. RANGE |
Can be adjusted by internal potentiometer A type only |
||||||
SETUP, RISE TIME |
500ms, 100ms at 95% load 230VAC | ||||||
|
|
|
ELG-150-36 | ELG-150-42 | ELG-150-48 | ||
|
VOLTAGERANGE |
180 ~ 295VAC 255 ~ 417VDC |
|||||
FREQUENCYRANGE | 47 ~ 63Hz | ||||||
EFFICIENCY |
88% |
89% |
90% |
90% |
90% |
||
AC CURRENT | 0.9A / 230VAC 0.7A/277VAC | ||||||
INRUSH CURRENT |
COLD START 65A(twidth=550 s measured at 50% Ipeak) at 230VAC |
||||||
LEAKAGE CURRENT |
<0.75mA / 277VAC | ||||||
POWER FACTOR | PF 0.95/230VAC PF 0.92/277VAC at full load | ||||||
TOTAL HARMONIC DISTORTION |
THD< 20% when output loading 60% at 115VAC/230VAC input and output loading 75% at 277VAC input |
Model |
|
|
ELG-150-36 | ELG-150-42 | ELG-150-48 | |||||||
PROTECTION |
SHORT CIRCUIT | 95 ~ 108%, Constant current limiting, recovers automatically after fault condition is removed | ||||||||||
OVER VOLTAGE |
14~18V |
28~34V |
41~48V | 47~54V | 54~62V | |||||||
Shut down o/p voltage with auto-recovery or re-power on to recovery |
||||||||||||
OVER TEMPERATURE |
Shut down o/p voltage, recovers automatically after temperature goes down |
|||||||||||
|
WORKING TEMP |
-40 ~ +85°C (Refer to Derating Curve) |
||||||||||
WORKING HUMIDITY |
20 ~ 95% RH non-condensing |
|||||||||||
STORAGE TEMP,HUMIDITY |
-40 ~ +90C, 10 ~ 95% RH |
|||||||||||
TEMP. COEFFICIENT |
±0.03%/QC (0 ~ 50C) |
|||||||||||
|
SAFETY STANDARDS |
UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent, IP65 or IP67, J61347-1, J61347-2-13 approved |
||||||||||
WITHSTAND VOLTAGE |
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC |
|||||||||||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH |
|||||||||||
EMC EMISSION |
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3 |