Product Details:
Payment & Shipping Terms:
|
| Driver Brand: | MEANWELL | Input Voltage: | 100 ~ 305VAC 142 ~ 431VDC |
|---|---|---|---|
| Output Power: | 240W | Output Type: | Single |
| Output Voltage: | 12/24/36/42/48V/54V | Output Current: | 10/6.66/5.71/5/4.45A |
| The Shell Material: | Metal | Warranty: | 5 Years |
| Certifications: | CE CB EMC UL TUV PSE | Efficiency: | 92~93% |
| Working Tempera: | -40~90℃ | Demension: | 199 63 * *35.5mm (L*W*H) |
| Output Frequency:: | 50/60Hz | Packing: | White Box,Brown Box |
| Highlight: | constant current power supply,meanwell led driver |
||
Mean Well 180~240W Constant Voltage Constant Current LED Driver ELG-240
Description
ELG-240 series is a 240W AC/DC LED driver featuring the dual mode constant voltage and
constant current output. ELG-240 operates from 100 305VAC and offers models with different~rated voltage ranging between 24V and 54V. Thanks to the high efficiency up to 93%, with the
fanless design, the entire series is able to operate for -40°C ~ +90°C case temperature under free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series
to fit both indoor and outdoor applications. ELG-240 is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
Features
![]()
Packaging Details
Special protective exporting LED Driver carton,Packing: 199 63 * *35.5mm (L*W*H), 0.75kg; 16pcs/13kg/0.72CUFT
MEAN WELL 240W ELG-240 IP67 rainproof pwm dali dimming led driver
Delivery Time
Shipped in 3 days after payment
| Model | ELG-240 |
| Rated Power | 240W |
| Input Voltage | 180 ~ 295VAC |
| Output Voltage | 24V 36V 42V 48V 54V |
| Warranty | 5 Years |
| IP | IP 67 |
POWER SUPPLY DEC
|
Model
|
ELG-240-24
|
ELG-240-36
|
ELG-240-42 | ELG-240-48 | ELG-240-54 | |
|
Output
|
DC VOLTAGE
|
24V
|
36V
|
42V | 48V | 54V |
|
CONSTANT CURRENT REGION
|
12~24V
|
18~36V | 21~42V | 24~48V | 27~54V | |
|
RATED CURRENT
|
10A
|
6.66A
|
5.71A | 5.0A | 4.45A | |
|
Rated POWER
|
240W
|
239.76W
|
239.82W | 240W | 240.3W | |
|
RIPPLE & NOISE (max.)
|
200mVp-p
|
250mVp-p
|
250mVp-p
|
250mVp-p
|
350mVp-p
|
|
|
CURRENT ADJ. RANGE
|
Can be adjusted by internal potentiometer A type only
|
|||||
|
Model
|
ELG-240-24
|
ELG-240-36
|
ELG-240-42 | ELG-240-48 | ELG-240-54 | ||
|
Input |
VOLTAGE RANGE
|
180 ~ 295VAC
|
|||||
|
FREQUENCY RANGE
|
47 ~ 63Hz
|
||||||
|
POWER FACTOR
|
PF>0.98/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
|
||||||
|
TOTAL HARMONIC DISTORTION
|
THD< 20% when output loading 60% at 115VAC/230VAC input and output loading 75% at 277VAC input
|
||||||
|
EFFICIENCY
|
92%
|
92%
|
92.5% | 93% | 93% | ||
|
AC CURRENT (Typ.)
|
0.6A / 230VAC 0.5A/277VAC
|
||||||
|
INRUSH CURRENT
|
COLD START 60A(twidth= s measured at 50% Ipeak) at 230VAC
|
||||||
|
MAX. No. of PSUs on 16ACIRCUIT BREAKER
|
3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
|
||||||
|
LEAKAGE CURRENT
|
<0.75mA / 277VAC
|
||||||
| Model | ELG-240-24 | ELG-240-36 | ELG-240-42 | ELG-240-48 | ELG-240-54 | |||||
PROTECTION |
SHORT CIRCUIT | 95 ~ 108%, Constant current limiting,recovers automatically after fault condition is removed | ||||||||
OVER VOLTAGE |
28~34V | 41~48V | 47~54V | 54~62V | 62~72V | |||||
| Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery | ||||||||||
| OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | |||||||||
| Model | ELG-240-24 | ELG-240-36 | ELG-240-42 | ELG-240-48 | |
ENVIRONMENT |
WORKING TEMP | -40 ~ +95°C (Refer to "Derating Curve") | |||
| WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||
| STORAGE TEMP., HUMIDITY | -40 ~ +80C, 10 ~ 95% RH | ||||
| TEMP. COEFFICIENT | ±0.03%/QC (0 ~ 50C) | ||||
| Model | ELG-240-24 | ELG-240-36 | ELG-240-42 | ELG-240-48 | ELG-240-54 | |
SAFETY EMC |
SAFETYSTANDARDS | UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent, IP65 or IP67, J61347-1, J61347-2-13 approved | ||||
| WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC | |||||
| ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH | |||||
| EMC EMISSION | Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3 | |||||
Contact Person: Mr. James
Tel: + 86 13410844021
Fax: 86-755-36607480